Crystal nVisionPressure calibrator
Reference pressure recorder
Ultra high precision, can replace the weight tester
Strong and durable, can be put into 3 feet of water
Easy to carry, can be calibrated at any position
- absolute pressure gauge / data recorder, the maximum working pressure of 15000 psi / 1000 bar / 100MPa
• differential reading accuracy up to 0.025%
Switch, voltage, current and temperature
• 500 thousand data points - read 10 readings per second from the 2 modules
You'll never find a better instrument!
Wear all replaceable CPF adapter in place
• graphical display of real-time data without PC
• connect with PC to view real time readings, or export to tamper proof digital records
• temperature compensation for -20 to 50 DEG C
• calibration certificate is provided by the A2LA accredited laboratory to provide test data for 5 different temperatures
option
-N CPFNPT connector kit (part number 4013) includes MPF-1/8QTF, MPF-1/4QTF and MPF-1/2QTF)
-B CPF BSP connector kit (part number 4015) includes MPF-1/8BSPF, MPF-1/4BSPF, MPF-3/8BSPF and MPF-1/2BSPF)
parts
5177 magnetic sling
4087 flexible portable box; rugged padded case, with nVision and accessories (including) independent pockets.
3985 protective cover; blue, resistant to Skydrol (included).
3951 Mini USB cable (included)
494764 ft (20 m) USB A female connector for USB A male connector active extension cable. Part 3951 of the cable can be connected together, with a total length of 134 ft (43.6 m). Warning: do not use the USB interface in hazardous atmospheres.
3952 test lead kit; two (1.8 m) 2mm test lead with Banana plug, with multi-function clip (MA20 module comes with).
3953 RTD connection kit; IP67 junction box connector (RTD module not included)
41263 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 48 in long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-1 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 13 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-3 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 20 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-5 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 26.2 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-10 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 49.2 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-11 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 80 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-12 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 4 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 75 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-7 3 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 12 "x 3/16" (diameter), with 316SS probe, 3 line system, RTD sensor wire spring connector, teflon insulation and 48 in long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
44913 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance 100 ohm, 4 x 4 mm (diameter), with 316SS probe, 3 stranded wire line single sensor RTD connector, spring wire, teflon insulation and a length of 4 M. Temperature range: -40 to 100 C (-40 to 212)
4623-2 4 line single sensor standard temperature of RTD, Pt/385/A3, precision 0.03%, resistance of 100 ohm, 4 "x 1/4" (diameter), with 316SS probe, 4 line system, RTD sensor wire spring connector, teflon insulation and 60 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-6 4 line single sensor standard temperature of RTD, Pt/385/A3, precision 0.03%, resistance of 100 ohm, 4 "x 1/4" (diameter), with 316SS probe, 4 line system, RTD sensor wire spring connector, teflon insulation and 100 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-8 4 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 6 "x 3/16" (diameter), with 316SS probe, 4 line system, RTD sensor wire spring connector, teflon insulation and 150 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
4623-9 4 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 6 "x 3/16" (diameter), with 316SS probe, 4 line system, RTD sensor wire spring connector, teflon insulation and 300 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)
47484 line single sensor standard temperature of RTD, Pt/385/B, precision 0.12%, resistance of 100 ohm, 6 "x 3/16" (diameter), with 316SS probe, 4 line system, RTD sensor wire spring connector, teflon insulation and 100 ft long stranded wire. Temperature range: -40 to 100 C (-40 to 212)