Fluke i30交流\直流电流钳
Fluke i30交流\直流电流钳,文章来源于福禄克,Fluke i30交流\直流电流钳基于霍尔效应技术,用于测量直流和交流电流。i30可与万用表、记录仪和其他合适的记录仪器结合使用,以实现准确的非侵入式电流测量。The i30 current clamp is basedon Hall effect technology for usein measurement of both dc andac current. The i30 may be usedin conjunction with multimeters,recorders and other suitablerecording instruments for accuratenon-intrusive current measurement.
Specifications
深圳银飞有售Fluke i30交流\直流电流钳
Fluke i30交流\直流电流钳主要特点:
1、基于霍尔效应技术的电流钳,可测量直流和交流电流
2、包括香蕉插头端,与万用表兼容
3、电流范围:30 mA 至 30 A DC,30 mA 至 20 A AC rms
4、频率范围:DC 至 20 kHz (-0.5 dB)
5、CAT III 300 V安全等级
KEY FEATURES:
• Current clamp based on Hall Effect technology that measures both DC and AC current
• Includes banana plug end for compatibility with multimeters
• Current range: 30 mA to 30 A DC, 30 mA to 20 A AC rms
• Frequency range: DC to 20 kHz (0.5 dB)
• SAFETY RATING: CAT III 300 V
|
Fluke i30交流\直流电流钳产品规格:
电气规格 | |
额定电流范围 | 30 mA 至 30 A DC,30 mA 至 20 A交流有效值 |
可用电流范围 | 5 mA 至 30 A DC,30 mA 至 20 A AC rms |
波峰因数 | 1.4 英寸 |
输出灵敏度 | 100毫伏/安 |
精度 (at +25°C) | 直流±读数的1%±2 mA AC±读数的0.5 dB±2 mA |
分辨率 | ±1毫安 |
负载阻抗 | > 10k欧姆和 ≤ 100pF |
导体位置灵敏度 | 相对于中心读数±1% |
频率范围 | 直流至 20kHz(-0.5 dB) |
温度系数 | 读数的±0.01%/℃ |
电源 | 9V碱性电池,MN1604/PP3,30 小时,低电量指示灯 |
工作电压(见安全标准部分) | 300V交流有效值或直流 |
一般规格 | |
最大导体尺寸 | 直径 19 mm |
输出连接 | 4 mm 安全连接器 |
输出零点 | 通过指轮手动调整 |
电缆长度 | 1.5米 |
工作温度范围 | 0℃ 至 +50℃ |
存储温度范围(取出电池) | -20℃ 至 +85℃ |
工作湿度 | 15% 至 85%(非冷凝) |
重量 | 250 克 |
安全 | IEC 61010-1,污染等级2 |
IEC 61010-2-032:CAT III 300V | |
在未绝缘导体上使用探头仅限于300 V交流有效值或直流, 频率低于1 kHz。 |
|
EMC兼容性 | IEC 61326-1:便携式电磁环境 |
General specifications | |
Maximum conductor size | 19 mm (.748 in) diameter |
Output connection | 4 mm (.157 in) safety connector |
Output zero | Manual adjust via thumbwheel |
Cable length | 1.5 m (4.91 ft) |
Operating temperature range | 0℃ to +50℃(32°F to 122°F) |
Storage temperature range (with battery removed) | -20℃ to +85℃ (-4°F to 185°F) |
Operating humidity | 15 % to 85 % (non-condensing) |
Dimensions (HxWxD) | 183 mm x 71 mm x 25 mm (7.2 in x 2.8 in x 1 in) |
Weight | 250 g (.55 lb) |
Electrical specifications | |
Specified current range | 30 mA to 30 A DC, 30 mA to 20 A AC rms |
Usable current range | 5 mA to 30 A DC, 30 mA to 20 A AC rms |
Crest Factor | 1.4 |
Output sensitivity | 100 mV/A |
Accuracy (at +25℃) | DC±1 % of reading±2 mA AC±0.5 dB of reading±2 mA |
Resolution | ±1 mA |
Load impedence | > 100 k Ohms and ≤ 100 pF |
Conductor position sensitivity | ± 1 % relative to center reading |
Frequency range | DC to 20 kHz (0.5 dB) |
Temperature coefficient | ±0.01 % of reading/℃ |
Power supply | 9 V Alkaline, IEC 6LR61,30 hours, low battery indicator |
Working voltage (see safety standards) | 300 V AC rms or DC |