小巧便捷大容量Fluke961USB型温湿度记录仪
• USB直读PDF报告,无需安装软件
• 32000组数据,满足长时间记录
• 最小记录间隔时间10秒,应对环境急剧变化的情况
• 符合 FDA 21 CFR Part 11,数据可溯源
• 多种数据导出及报告格式
• 1米防跌落,防护等级IP65
• 设计小巧轻便,便于随时记录及读取
- USB direct read PDF report, no need to install software
- 32000 data sets for long time recording
- Minimum recording interval of 10 seconds for rapid environmental changes
- FDA 21 CFR Part 11 compliance and data traceability
- Multiple data export and report formats
- 1 meter drop protection with IP65 rating
- Compact and lightweight design, easy to record and read at any time
|
【关键指标-食品冷链】
Key Indicators-Food Cold Chain, GB 31605-2020《National Standard for Food Safety - Hygienic Code for Food Cold Chain Logistics》requirements:The transportation means shall be checked before loading, and the compartments shall be pre-cooled according to the transportation temperature of the food, and the temperature required for food transportation shall be reached before the beginning of transportation. The temperature during transportation should be continuously monitored in real time, and the recording interval should not be more than 10 min, and should be true and accurate.When the temperature of the transportation equipment exceeds the set range, corrective action and emergency measures should be taken immediately, and the range and time of over-temperature should be recorded truthfully. Transportation tools should take security measures during transportation, such as sealing or locking. The transportation process should be kept smooth, and when loading and unloading, it should be acted quickly and lightly, and minimize the number of times and time that the door of the car is opened.before distribution should confirm the integrity of food logistics packaging. The temperature meets the requirements.need to freeze the food in the transportation process temperature should not be higher than -18 C; need to refrigerate the food in the transportation process temperature should be 0°C ~ 10°C.
“香蕉运输理想的环境是13~15℃,湿度为90~95%。我们使用Fluke 961温湿度记录仪记录香蕉从采摘、装货、海运及陆运、交接及验收全流程的温湿度数据,一方面是保证香蕉的较好的口感及品质,另一方面也帮助我们规避了与承运方之间的纠纷,一旦发生意外,我们可以非常方便的导出全程的数据,作为重要依据来评估。”
——某香蕉种植基地,张先生
"The ideal environment for banana transportation is 13 to 15 degrees Celsius with 90 ~ 95% humidity. We use Fluke 961 temperature and humidity recorder to record the temperature and humidity data of the whole process of bananas from picking, loading, sea and land transportation, handover and acceptance, on the one hand, it is to ensure the best taste and quality of bananas, and on the other hand, it also helps us to avoid the disputes with the carriers, and in case of accidents, we can very conveniently export the data of the whole process, which can be used as an important basis for evaluation. "
--A banana plantation, Mr. Zhang
|
【关键指标-研发测试】
Key Indicators - R&D Testing, Timed recording, data export can be analyzed, In the R&D and testing process of many electronic, electromechanical and large-scale key equipment, temperature rise testing is an essential part. The board test usually uses a thermal imaging camera to quickly find hot spots, but the temperature rise test of the whole closed box is a difficult problem.
“之前我们使用热电偶来测试温升过程,但是产品组装完成后能否达到原先的设计要求,或者在长时间工作后是否依然能保持理想状态, 对我们来说是个难题。现在我们使用Fluke 961C温湿度记录仪,只需将探头找个小的空隙放进去,即可自动每隔1分钟记录箱体内的温度和湿度数据, 也可以通过主机来实时观察变化。最重要的是, 测试完成后,数据可以完整导出,我们可以进行二次分析,并存档。”
——某负载设备研发部,邹工
"Previously, we used thermocouples to test the temperature rise process, but it was difficult for us to determine whether the product could meet the original design requirements after assembly, or whether it could maintain the ideal condition after a long period of operation. Now we use Fluke 961C temperature and humidity logger, just put the probe to find a small gap, you can automatically record the temperature and humidity data in the box every one minute, you can also through the host computer to observe the changes in real time. Most importantly, after the test is completed, the data can be exported in its entirety so that we can analyze it twice and archive it."
--Mr. Zou, R&D Department of a load equipment.
|
【关键指标-关键设备】
Key Indicators - Key Equipment, Multi-level over-limit alarm, high-capacity data storage, Computer room is generally divided into class A, class B and class C, the requirements for the three types of computer rooms are not the same, the standard is reduced in turn. For temperature and humidity, the requirements of Class A and Class B computer rooms are the same, the temperature is 23±1℃, and the humidity is 40%~55% RH. The temperature of Class C computer rooms is 18~28℃, and the humidity is35%~75%.
“最近我们的交换机总是频繁出现温度报警,来来回回查了很多次都没法找到超温的原因,大大影响了我们工业4.0网络改造的项目计划。多此与交换机厂家沟通,但是得到的建议是房间空调有问题,建议我们改造空调系统。谢谢Fluke为我们及时提供了961C型的温湿度记录仪,我们将961放在了交换机的几个重要发热点进行了48小时不间断的记录,并设置了重要限制的超限报警,最后发现所有温度及湿度数据都是正常的,并未超过限制,实际是交换机自带的温度传感器出现了问题,我们随即要求的供应商进行维修,问题再也没有复现。”
——某大型制造企业网络部,王工
"Recently, our switches have been experiencing frequent temperature alarms, and we have gone back and forth many times without being able to find the cause of the over-temperature, which greatly affected our project plan for the renovation of our Industry 4.0 network. We communicated with the switch manufacturer, but the advice we got was that there was something wrong with the room air conditioner, and we were advised to remodel the air conditioning system. Thank Fluke for providing us with 961C type temperature and humidity recorder in time, we will 961 placed in the switch of several important hot spots for 48 hours of uninterrupted recording, and set up an important limit of over-limit alarms, and finally found that all the temperature and humidity data are normal, and did not exceed the limit, the actual switch comes with a temperature sensor problem, we then asked the supplier to repair, and the problem never returned. vendor for repair, and the problem never recurred."
--Mr. Wang, Network Department of a Large Manufacturing Enterprise
|